Understanding the Unit Settings
Inverter Setting
In0 Inverter is disabled, unit will not provide backup function when utility power is not
available
In1
Inverter is set to standby mode with power save mode OFF. Unit will provide
backup function when utility power is not available
In2 Inverter is set to standby mode with power save mode ON. Unit will provide
backup function only when utility power is not available AND the load connected
to the output is >10W.
Note: Unit will turns ON every 10 s to check on the power consumption.
Charger Current Setting
5A – 40A
5A – 55A
Bulk/Float current setting:
IC121040: 5A/1.5A, 10A/2A, 20A/3A, 40A/4A
IC122055: 5A/1.5A, 15A/3A, 35A/4A, 55A/6A
Battery Type and Voltage Setting (Bulk/Absorption/Float)
FLo Flooded: 14.4V / 14.4V / 13.5V
GEL GEL: 14.2V / 14.2V / 13.8V
AG AGM: 14.3V / 14.3V / 13.4V
Fi Fixed: 13.5 Vdc fixed voltage
Battery Under Voltage Setting
SdL Battery under voltage setting is set to LOW (setting used for normal operation)
Under voltage alarm: 11.0 Vdc
Under voltage alarm recovery: 11.3 Vdc
Under voltage shutdown: 10.5 Vdc
Under voltage recovery: 12.0 Vdc
SdH Battery under voltage setting is set to HIGH (setting to avoid battery over
discharge when connected to car start battery)
Under voltage alarm: 12.1 Vdc
Under voltage alarm recovery: 12.3 Vdc
Under voltage shutdown: 11.8 Vdc
Under voltage recovery: 12.6 Vdc
Alarm Setting
AL0 Fault and warning audible alarm is disabled. Display panel only shows error code
and audible alarm will not sound.
AL1 Audible alarm will sound when fault or warning occurs.
Maximum Shore Power Current Draw Setting
IC121040 IC122055
AC Load current Charger
Current
AC Load Current Charger
Current
Set the maximum current draw from shore power to 15A. The maximum current
draw from unit is set to match with the shore power circuit breaker rating to avoid
tripping of the shore power circuit breaker during the by-pass mode. Battery
charging current will automatically reduce when there is a high demand on AC
load during the by-pass mode.
>11Aac 5 Adc >11Aac 5 Adc
>10Aac and <12Aac 10 Adc >6Aac and <11Aac 15 Adc
>5Aac and <10Aac 20 Adc >1Aac and <6Aac 35 Adc
Cb1
<5Aac 40 Adc
<1Aac 55 Adc
Same as above. Set the maximum current draw from shore power is 20A
>16Aac 5 Adc >16Aac 5 Adc
>15Aac and <17Aac 10 Adc >11Aac and <16Aac 15 Adc
>10Aac and <15Aac 20 Adc >6Aac and <11Aac 35 Adc
Cb2
<10Aac 40 Adc
<6Aac 55 Adc
Same as above. Set the maximum current draw from shore power is 30A Cb3
>26Aac 5 Adc >26Aac 5 Adc