True Sinewave Power Inverter
SW 1204 series
Modified Sinewave Power Inverter
MW 1204 series
Owners Manual
For safe and optimum performance, the Power Inverter must be used properly. Carefully read and follow all
instructions and guidelines in this manual and give special attention to the CAUTION and WARNING
statements.
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE
Disclaimer
While every precaution has been taken to ensure the accuracy of the contents of this guide, KISAE
Technology assumes no responsibility for errors or omissions. Note as well that specifications and
product functionality may change without notice.
Important
Please be sure to read and save the entire manual before using your KISAE Power Inverter. Misuse
may result in damage to the unit and/or cause harm or serious injury. Read manual in its entirety before
using the unit and save manual for future reference.
Product Numbers
True Sinewave series
SW 1204 120V 400W true Sinewave power inverter with USB port
SW 1204i 230V 400W true Sinewave power inverter with USB port
Modified Sinewave series
MW 1204 120V 400W modified Sinewave power inverter
Thank you for purchasing the KISAE Power Inverter. With our state of the art, easy to use design, this
product will offer you reliable service for providing AC power for your home, cabin, RV or Trailer. The
KISAE Power Inverter can run many AC-powered appliances when you need AC power anywhere.
This manual will explain how to use this unit safely and effectively. Please read and follow these
instructions and precautions carefully.
IMPORTANT SAFETY INFORMATION
This section contains important safety information for the KISAE Power Inverter. Each time, before
using the KISAE Power Inverter, READ ALL instructions and cautionary markings on or provided with
the inverter, and all appropriate sections of this guide.
The KISAE Power Inverter contains no user-serviceable parts. See Warranty section for how to handle
product issues.
WARNING: Fire and/or chemical burn hazard
• Do not cover or obstruct any air vent openings and/or install in a zero-clearance compartment.
WARNING: Failure to follow these instructions can result in death or series injury
• When working with electrical equipment or lead acid batteries, have someone nearby in case of an
emergency.
• Study and follow all the battery manufacturers specific precautions when installing, using and
servicing the battery connected to the inverter.
• Wear eye protection and gloves.
Avoid touching your eyes while using this unit.
• Keep fresh water and soap on hand in the event battery acid comes in contact with eyes. If this
occurs, cleanse right away with soap and water for a minimum of 15 minutes and seek medical
attention.
• Batteries produce explosive gases. DO NOT smoke or have an open spark or fire near the system.
• Keep unit away from moist or damp areas.
Avoid dropping any metal tool or object on the battery. Doing so could create a spark or short circuit
which goes through the battery or another electrical tool that may create an explosion.
WARNING: Shock Hazard. Keep away from children!
Avoid moisture. Never expose unit to snow, water etc.
• Unit provides 120 VAC, treat AC output sockets the same as regular wall AC sockets at home.
WARNING: Explosion hazard!
• DO NOT use the KISAE Power Inverter in the vicinity of flammable fumes or gases (such as propane
tanks or large engines).
AVOID covering the ventilation openings. Always operate unit in an open area.
LIMITATIONS ON USE
Do not use in connection with life support systems or other medical equipment or devices.
1. INTRODUCTION
SW1204 Series
MW1204 Series
Service Contact Information
Email: info@kisaetechnology.com
Phone : 1 604 320-7857
Web : www.kisaetechnology.com
The KISAE Power Inverter package includes the items list below.
• Power Inverter base unit
• Owners manual
• DC Input cable accessories
WARNING: KISAE Technology recommends that all wiring be done by a certified technician or electrician
to ensure adherence to the applicable electrical safety wiring regulations and installation codes. Failure to
follow these instructions can damage the unit and could also result in personal injury or loss of life.
CAUTION: Before beginning your power inverter Installation, please consider the following:
• The KISAE Power Inverter base unit should be used or stored in an indoor area away from direct sunlight,
heat, moisture or conductive contaminants.
• When placing the unit, allow a minimum of three inches of space around the unit for optimal ventilation.
Understanding the unit features
SW1204 series: MW1204 series:
2. PRODUCT DESCRIPTION
3. INSTALLATION
Power Inverter
SW1204
MW1204
AC
LOADS
Pos +
Neg -
Disconnect
Switch
Fuse or Circuit
Breaker
12 V Battery Bank
(Charger system
sold separately is
required to charge
the battery bank
when battery is
discharged)
Material Prepare for Installation
Typical Wiring block diagram of the Power Inverter:
12V Battery Bank:
• The use of deep cycle battery is highly recommended for power inverter application
• For battery size, you need to identify how much you will be using them between charges. KISAE do
recommends you purchase as much battery capacity as possible. See more on Battery Run time and
Load in Section 4.
Fuse or Circuit Breaker:
• DC-rated fuse or DC-rated circuit breaker connected along the DC positive line is required.
• Select a fuse or circuit breaker with a minimum of 60 ADC.
• Based on the size of the battery bank chosen on the 12V Battery Bank above, determine the overall
short circuit current rating of the battery bank from the battery manufacturer. The fuse or circuit
breaker chosen has to be able to withstand the short circuit current that may be generated by the
battery bank.
Disconnect Switch:
• Select a Disconnect Switch with the same or higher the rating of the selected fuse or circuit breaker
from the above.
• The Disconnect Switch is used to disconnect the DC power between the power inverter and the
battery bank during service, maintenance or trouble shooting.
DC Input Cable:
• Use of low resistance wire is required for all the DC connections between the inverter and the battery
bank.
• Uses minimum #10 AWG wire with maximum cable length of 5 feet.
Installing the Power Inverter System
WARNING: Electrical Shock Hazard
The unit ‘On/Off’ switch does not disconnect the DC power from the battery. Use the DC Disconnect Switch
or disconnect the DC input cables connection to disconnect the DC power from the battery before working
on any circuits connected to the unit. Failure to follow these instructions can result in death or serious injury.
CAUTION: Reverse the DC Input terminal will damage the unit and cannot be repaired. Damage caused
by reverse polarity connection is not covered by the warranty.
Power Inverter Installation (SW1204 series only):
• Choose an appropriate mounting location.
• For indoor use, the orientation of the unit can be mounted in any direction except with the DC Input
panel facing downwards.
• For RV installation, the unit has to be mounted flat on horizontal surface.
• Use mounting template below to mark the positions of the mounting screws.
• Drill the 4 mounting holes and place the inverter in position and fasten the inverter to the mounting
surface.
‘Power’ indicator
‘Fault’ indicator
USB
On/Off Switch
Fan
opening
DC Input
Terminals
147.0mm
161.0mm
EU 230V 120V AU 230V UK 230V
Picture shown
SW1204 series
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Owner’s Manual

True Sinewave Power InverterSW 1204 seriesModified Sinewave Power InverterMW 1204 seriesOwner’s ManualFor safe and optimum performance, the Power Inve

Page 2 - GFCI Duplex

Power Inverter DC Input Connection:• Connect one end of the negative DC input cable to the Power Inverter DC negative terminal (black). Conn

Commentaires sur ces manuels

Pas de commentaire